Please use this identifier to cite or link to this item: http://nuir.lib.nu.ac.th/dspace/handle/123456789/6305
Full metadata record
DC FieldValueLanguage
dc.contributorAkekachai Pannawanen
dc.contributorเอกชัย พรรณวัลย์th
dc.contributor.advisorSakda Somkunen
dc.contributor.advisorศักดา สมกุลth
dc.contributor.otherNaresuan Universityen
dc.date.accessioned2024-09-25T03:02:39Z-
dc.date.available2024-09-25T03:02:39Z-
dc.date.created2023en_US
dc.date.issued2023en_US
dc.identifier.urihttp://nuir.lib.nu.ac.th/dspace/handle/123456789/6305-
dc.description.abstractCombining residential energy storage with solar photovoltaic (PV) power generation within low-voltage distribution networks holds promise for attaining energy self-sufficiency. This research presents the design and implementation of such an approach using a 3-kW single-phase grid-connected battery inverter. The inverter pairs a 51.2-V lithium iron phosphate battery pack witha 220-V, 50-Hz grid. Its prototype design incorporates both an LCL-filtered voltage source converter (VSC) and a dual active bridge (DAB) DC-DC converter, both operating at a 20 kHzswitching frequency. The VSC employs a swift DC bus voltage control strategy alongside a comprehensive approach to mitigate current harmonics. Similarly, the DAB DC-DC converter integrates a proportional-integral regulator to efficiently manage the average battery current, incorporating dynamic DC offset mitigation for the medium-frequency transformer’s currents within its single-phase shift modulation scheme. The control strategies for both converters are executed on a 32-bit TMS320F280049C microcontroller within the same interrupt service routine, demonstrating the integration of control systems to enhance performance. This study introduces a synchronization technique aligning the switching signal generation of both converters with the sampling of analog signals for the control system, ensuring coordinated operations. The prototype inverter exhibited exceptional performance, achieving an efficiency exceeding 90% and maintaining total harmonic distortion in the grid current below 1.5% at a battery power output of ±1.5 kW, suggesting its potential to enhance grid stability and energy efficiency.en
dc.description.abstract-th
dc.language.isoenen_US
dc.publisherNaresuan Universityen_US
dc.rightsNaresuan Universityen_US
dc.subjectBattery storage; DC-DC converter; grid-connected inverter; solar photovoltaic.th
dc.subjectDual Active Bridge (DAB) DC-DC converteren
dc.subjectLCL-filtered Voltage Source Converter (VSC)en
dc.subjectBattery storage; DC-DC converter; solar photovoltaic.en
dc.subject.classificationEngineeringen
dc.subject.classificationElectricity, gas, steam and air conditioning supplyen
dc.titleAnalysis and Design of Single-Phase Grid-Connected Battery Inverter Using Dual Active Bridge DC-DC converteren
dc.title-th
dc.typeThesisen
dc.typeวิทยานิพนธ์th
dc.contributor.coadvisorSakda Somkunen
dc.contributor.coadvisorศักดา สมกุลth
dc.contributor.emailadvisorsakdaso@nu.ac.then_US
dc.contributor.emailcoadvisorsakdaso@nu.ac.then_US
dc.description.degreenameDoctor of Philosophy (Ph.D.)en
dc.description.degreenameปรัชญาดุษฎีบัณฑิต (ปร.ด.)th
dc.description.degreelevelDoctoral Degreeen
dc.description.degreelevelปริญญาเอกth
Appears in Collections:วิทยาลัยพลังงานทดแทนและสมาร์ตกริดเทคโนโลยี

Files in This Item:
File Description SizeFormat 
AkekachaiPannawan.pdf14.1 MBAdobe PDFView/Open


Items in NU Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.